Note Author Title/Description

25

Lewis Detection of Carbamates in Water Based on Conditions Defined in EPA Method 531.1
Key Words: Carbamates, Pesticides, PCR, Fluorescence, Environmental, EPA

24

Lewis HPLC Analysis of Explosives using EPA Method 8330
Key Words: Explosives, EPA, HPLC

23

Lewis Analysis of Dietetic Soft Drinks
Key Words: Aspartame, Caffeine, Benzoic Acid, Saccharin, Beverages

22

Lewis Isocratic Analysis of Aspartame in Diet Beverages
Key Words: Aspartame, Beverages, Isocratic Analysis

21

Lewis Analysis of Bentazone and Phenoxyacid Herbicides in Water Samples using Automated

On-Line Solid-Phase Extraction;

Key Words: Phenoxyacid Herbicides, Bentazone, Solid Phase Extraction, 9200 Prospekt

20

Terry Prospekt Automated Sample Preparation for Tricyclics
Key Words: Prospekt, TCA, Tricyclic Amines, Solid Phase Extraction, SPE

19

Klink Analysis of Phenols in Water with Star 9080 EC Detector
Key Words: Star 9080, Phenols, Environmental

18

Klink Pulsed Amperometric Detection of Disaccharides with Star 9080 Detector
Key Words: Star 9080, Sugars, Food

17

Klink Amino Acid Neurotransmitter Analysis with Star 9080 EC Detector
Key Words: Star 9080, Amino Acids, Clinical, Biomedical

16

Klink Catecholamine Analysis with Star 9080 EC Detector
Key Words: Star 9080, Catecholamines, Clinical, Biomedical

15

Davies Identification and Quantitation of Co-eluting Non-steroidal Anti-inflammatory Drugs by Diode Array Detection; Ilona Davies
Key Words: Fast HPLC, Diode Array Detector, Non-steroidal Anti-inflammatory Drugs, NSAIDs, Purity Parameter, PuP

14

Davies Automated On-line LC-GC for the Clean-up and Determination of PAH in Urban Air
Key Words: Automated, Clean-up, LC-GC, On-line, Polycylic Aromatic Hydrocarbon, PAH, Urban Air; Description: A Varian GC and Varian LC were combined on-line as an automated LC-GC System. This system was used to determine PAH in urban air particulates.

13

Davies Analysis of an X-ray Contrast Agent by LC-Diode Array-MS
Key Words: Atmospheric Pressure Chemical Ionization Interface, APCI, Contrast Agent, Diode Array Detector, Electrospray Ionization Interface, ESP, HPLC, Ionspray, Mass Spectroscopy, MS, Omnipaque

Description: A Varian LC-Diode Array System was interfaced to a mass spectrometer through either a high flow electrospray interface or an atmospheric pressure chemical ionization interface. This system was used to verify the purity and chemical structure of an x-ray contrast agent

12

Davies Analysis of Basic Drugs in Postmortem Blood by HPLC with Diode Array Detection
Key Words: Toxicology, Drug Identification, HPLC, Diode Array Detector, Blood, Purity Parameter, PuP, Forensic

Description: 121 drugs were identified in postmortem blood extracts by HPLC with diode array detection and PolyView Purity Parameters

11

Joseph

Application of Multicomponent Analysis to HPLC Diode Array Detection for the Quantitation of Partially Resolved Peaks
Key Words: Multicomponent Analysis, Quantitation, Diode Array Detection, Chromatographic Resolution, Paraquat, Diquat, PolyView, US EPA Method 549

Description: The official EPA chromatographic method for Paraquat and Diquat (two herbicides) does not fully resolve the compounds. The method requires dual wavelength detection, but when one compound is 10 times greater than the other, this method gives up to a 50% error in the amount calculated. MCA is able to give result accuracy within 4% for all mixtures

10

Joseph

Application of Multicomponent Analysis to HPLC Diode Array Detection for Quantitation of Unresolved Components
Key Words: Multicomponent Analysis, Quantitation, Diode Array Detection, Polyview, Chromatographic Resolution, Sunscreens

Description: Four cosmetic agents in sun screens were separated with a method which did not fully resolve the individual components. PolyView with Multicomponent Analysis (MCA) produced quantitative results with accuracy of better than 97% and precisions of less than 1%, even for completely fused peaks.

9

Huen

Identification and Quantitation of Herbicides and Pesticides in Water by LC & Diode Array Detector
Key Words: Pesticides, Herbicides, Triazines, Phenylurea Herbicides, Diode Array Detector, Library Search, Purity Parameters, HPLC, Empore, Solid Phase Extraction, Environmental;

Description: Pesticides and Herbicides can be found in ground water and drinking water. Sample Prep using Empore disks and gradient analysis with diode array detection provide automatic analysis, quantitation and peak identity confirmation through automated library searches using PolyView software.

8

Joseph

Identification of Polynuclear Aromatic Hydrocarbons in a Complex Matrix w/ Diode Array Detection
Key Words: Polynuclear Aromatic Hydrocarbons, PAHs (PNAs), Diode Array Detectors, Compound Identity, EPA 610, Waste Water, PolyView, Polychrom;

Description: Diode array detection is used to confirm the identity of PAHs after separation on three different environmental specialty columns. Specialty columns make it easy to get started in environmental analysis. The DAD with PolyView software provide peak identity confirmation.

7

Joseph HPLC Detector Options for the Determination of Polynuclear Aromatic Hydrocarbons
Key Words: Polynuclear Aromatic Hydrocarbons, PAHs, PNAs, UV, Fluorescence, Wavelength Optimization

Description: Polynuclear Aromatic Hydrocarbons (PAHs) can be detected by either UV detection of 254nm using EPA Method 610 or 550.1, by time programmed wavelength changes which enhance sensitivity up to 35 times, or by fluorescence detection which can enhance sensitivity up to 100 times.

6

Lai Enhancement of Selectivity in Sample Cleanup for Tobramycin in Serum Using Derivatization Solid Phase Extraction
Key Words: Pharmaceuticals, Tobramycin, OPA, Detection Enhancement, Selectivity Enhancement, Solid Phase Extraction, Sample Cleanup, Derivatization, Bond Elut

Description: Solid phase extraction is used to extract Tobramycin from plasma using Bond Elute cartridges. In order for the extraction to work, the drug is derivitized with OPA to make it less polar and, therefore, easier to separate from serum and to provide enhanced sensitivity.

5

Lai Enhancement of Detection Sensitivity of Tobramycin Using PreColumn Derivatization
Key Words: Pharmaceuticals, Tobramycin, OPA, AutoMix, Detection Enhancement, Fluorescence, Precolumn Derivatization, Varian 9100 AutoSampler

Description: Tobramycin is a pharmaceutical which has very low UV absorbance above 205nm making detection difficult, and is very polar minimizing its retention on a reverse phase column. Derivitization of Tobramycin with OPA gives excellent reverse phase retention and 1 picomole detection sensitivity with fluorescence detection. The detrivitization, separation and detection are fully automated using the 9100 AutoSampler, 9070 fluorescence detector, the 9010 and the Star Workstation.

4

Joseph

The Analysis of Milk Sugars with a Modern Refractive Index Detector and a Carbohydrate Column
Key Words: Sugars, Refractive Index Detection, Lactose, Glucose, Galactose, Carbohydrate Column;

Description: Sugars are a common analysis and the appropriate method can depend on a number of factors for the case of sugars in lactose reduced milk a speciality carbohydrate column provides excellent resolution and the refractive index provides adequate sensitivity.

3

Lai

Chiral Separation and Detection Enhancement of Propranolol Using Automated Precolumn Derivatization
Key Words: Pharmaceuticals, Propranolol, FLEC, AutoMix, Chiral, Enantiomers, Diastereomers, Racemic Mixtures, Detection Enhancement, Fluorescence, Precolumn Derivatization

Description: Propranolol is a pharmaceutical that is chiral and has low UV absorptivity. Chiral separation and detection enhancement are achieved by precolumn derivatization with FLEC, a chiral and fluorescent derivatization reagent. Automation is achieved by using the 9095 AutoSampler.

2

Mayer Amino Tag Pre-column Amino Acid Analysis
Key Words: Amino Acids, FMOC, Amino Tag, AutoMix, Precolumn Derivatization, Fluorescence;

Description: AminoTag is an automated Star HPLC based Precolumn amino acid derivatization technique with the reagent, FMOC (Fluorenylmethyl-Chloroformate).

1

Sullivan

Tschida

Aamodt

The Determination of N-methylcarbamate Pesticides in Water by HPLC
Key Words: Postcolumn Reaction System, OPA Derivatization, Fluorescence Detection

Description: Describes an automated, single point control system for Carbamate pesticide determination. Utilizes advanced safety and stability features of the Pickering postcolumn reaction system using OPA (o-Phthalaldehyde) derivatization.

 


HPLC News
Varian's Scanview application database is now available on-line

The popular Varian, Inc. Scanview database (includes over 4,000 applications) is now available on-line.


HPLC Resources
HPLC Product Information
Software Data Systems
Chromatography Support
News Releases
Events