Varian, Inc. is a global technology company that builds leading-edge tools and solutions for diverse, high-growth applications in life science and industry.
  網站地圖 招聘英才
FactorFour™ Columns
VF-1ms
VF-5ms
VF-5ht
VF-Xms
VF-624ms
VF-1301ms
VF-1701ms
VF-17ms
VF-23ms
VF-35ms
VF-200ms
VF-DA
 
FactorFour™

GC Columns

FactorFour VF-1701ms

World's first ultra-low bleed 14% cyanopropyl/phenyl, 86% PDMS GC column for pesticides, PCB's and semi-volatile organic compounds


Elute difficult analytes like p,p’-DDT
Perfect-peak shape for endrin aldehyde
Eliminate of ghost peaks & unstable baselines

The new ultra-low bleed FactorFour VF-1701ms columns offer a new standard in increased signal-to-noise ratio for environmental samples containing semi-volatile organic compounds, pesticides and PCB’s covered by EPA test methods 500, 600 and 8000 series, especially EPA 508, 525, 608, 625 and 8140/8141.

Elutes difficult analytes and gives perfect peak shape
Difficult trace analytes such as p,p’-DDT which regularly decompose and give rise to poor peak shape, such as endrin aldehyde, are now virtually eliminated. The result is a significant improvement in signal to noise ratio for your trace analytes - whether you are analysing concentrations as high as 200pg or as low as 2pg. See Figure 1.

Eliminates ghost peaks & unstable baselines
With the new ultra-low bleed VF-1701ms (bleed specification of 2pA @ 280 °C for a 60 m, 0.25μm, 0.25 mm ID column), reduced bleed means you can also benefit from virtual elimination of ghost peaks and unstable baselines – giving you more accuracy than ever before in your quantitations. See figure 2.

The VF-1701ms comes with EZ-GRIP™ simplifying installation, coupling and operation of capillary columns. For guaranteed performance the retention index, efficiency, selectivity and bleed is measured and specified on the test report supplied with each column.

Typical components analyzed with the VF-1701ms include
organic compounds in drinking water: EPA 524.2
base/neutrals and acids: EPA 625
PCB’s and chlorinated pesticides: EPA 508, 608, 808, 8082
organophosphorus pesticides and herbicides: EPA 507, 8081, 8140/8141, 8151

Similar other standard phases
DB-1701, Rtx-170, HP-1701, ZB-1701, Equity-1701, SPB-1701, CP-Sil 19 CB, CP-Sil 19 CB for Pesticides, OV-1701, 007-1701, BP-10,,T-1701, MEGA 1701, NB-1701, Optima-1701, Permabond OV-1701, TRB-1701, UA-1701, VB-1701


Companion Products
Gas Clean GC/MS Filter
GC Columns on 5-inch cage
Custom made GC Columns
Testmix
Retention Gaps

Support & Resources
Features
Brochures
Application Notes
Specifications
Press releases
Product support